- Pipe Size: 2 1/2"
- Complete Assembly Includes: 2 1/2" Flapper, 5520R Dial, 5305 Adapter, Screws, & Gasket
Taylor-Flo Indicators are installed in liquid pipelines to give visual indication of flow direction or the absence of flow of LP-Gas or Anhydrous Ammoni(NH3) at working pressures up to 500 psig [34 Bar]. Capable of showing flow in both directions, the indicator mounts in a standard tee fitting, using the supplied adaptor, with the flapper assembly in the center of the pipe.
The head, center shaft, support tube; bearings and vane in these indicators are made of 300 Series stainless steel.
The magnets are nickel-plated Alnico, and the threaded mounting adapters are forged steel. The hermetically sealed dial has a large 4” dial face capable of showing flow in both directions or the absence of flow.
Note: Torque mounting bolts to 140 to 150 in-lb.
This assembly requires a 2 1/2" X 2" Hex Bushing that is sold seperately.