- Tank Connection: 2" FNPT
- Includes: Manifold & 2 A1310A
- Relief Setting: 250 PSI
Includes a 2" X Close EH Seamless Nipple.
A1416A CFM Flow Rates with Reliefs Installed
Flow through Port # 1 with a 1310A PRV installed - 5,112 CFM Air*
Flow through Port # 2 with a 1310A PRV installed - 4,699 CFM Air*
Flow through Both Ports with 1310A PRV's installed - 8,602 CFM Air*
*Flow Capacity @ 120% of Set Pressure.
WARNING!
WHEN IN SERVICE, DO NOT USE A1416 WITH ONLY ONE PORT OPEN. TO GET PROPER CFM ALWAYS KEEP DIVERTER DISC IN CENTER POSITION. CLOSING PORT ONE OR TWO IS ONLY FOR CHANGING RELIEF VALVES. NEVER USE A PLUG IN PORT ONE OR TWO ON AN A1416 MANIFOLD.