Squibb Taylor
Call us: 1.800.345.8105

HSRL-CFC

Item Number123212
  • Inlet: 1" FNPT

  • Outlet: 1" FNPT

  • Outlet Pressure Range: 9 - 13" W.C.

  • Outlet Pressure Setting: 11" W.C.

  • Capacity in BTU/H LPG: 2,600,000 *

Case Quantity: 10 Pcs.

* Capacity in BTU per hour LPG:

     Based on 10 psi inlet pressure & 2" W.C. droop.

Type HSRL - Second-Stage regulators are Underwriters Laboratories (UL®) listed regulators designed to reduce the outlet pressure from a First-Stage regulator, usually 10 psi to 11 inches w.c., in domestic installations. Vents are screened with standard orientation over the inlet, but other orientations are available. Fisher® brand Second- Stage regulators are painted palm green for easy identification.

Type HSRL - is an UL listed regulator designed for light commercial applications up to 2,600,000 BTU per hour. It utilizes a high strength cast iron body and a 3/4 in. NPT drip lip vent design. The PFC and SFC feature an angle-body design. The design also includes a high capacity internal relief valve and a 20-year recommended replacement life.